Introduction about this JBD BMS:
This bms is especially for 14S Bluetooth or smart fixed configurations only. Basically it can also be used for any other lithium technologies even if LiFePo4, Lithium Ion, LiPo and Lithium Metal by changing internal parameters after connecting to Bluetooth App or computer. Most important that it is strictly for 14S battery packs only. As a result, that they cannot be used for any other battery pack Configurations.
In the same way all Parameters can be changed Via Bluetooth App or UART USB Connection with PC Monitoring Program .Default setting inside BMS are for lithium-ion batteries.
Over charge and over discharge protection:
The Lithium-ion battery pack will stop charge after the cell voltage reaches 4.2V and stop discharge when its voltage reaches 3V.
Temperature Protection:
- In high temperatures the bms ranges from 70℃ discharging battery protection.
- Meanwhile in low temperatures the bms ranges up to -20℃ battery protection.
What you will get:
- JBD 14S Smart Li-Ion 40A rated voltage with 48V BMS
- Balanced wire sense cable (15 Wire sense cable with connector)
- Bluetooth dongle
- Thermostat
- Instruction Manual
- Please use Xiao Xing App for Bluetooth Applications .The link is available in bms batteries website software downloads dropdown box
- This BMS is also used for all kinds of lithium-ion cells including 18650 ,21700,32650 prismatic cells.
DESCRIPTION | SPECIFICATION | |
---|---|---|
BATTERY TYPE | Li-ion cells(default) | Lifepo4 cells(if preferred) |
Recharging current | 40A | |
Discharging current | 40A | |
Peak current | 120A for 5 sec | |
Charger voltage (CC-CV) | S*4.2V | S*3.6V |
Charge Voltage | S*4.25V | S*3.75V |
Over-charge protection voltage | 4.250V | 3.650V |
Over-charge protection delay time | 1000mS | |
Over-charge protection recovery voltage | 4.180V | 3.450V |
Over-discharge protection voltage | 2.800V | 2.500V |
Balance release voltage | 4.18V | 3.5V |
Over-discharge protection delay time | 100mS | |
Over-discharge protection recovery voltage | 2.900V | 3.000V |
Over-discharge protection recovery condition | Disconnect load or Charging activation | |
Discharge overcurrent protection current value | 360A | |
Discharge overcurrent protection delay | 1000mS | |
Discharge overcurrent protection recovery condition | Disconnect load or Charging activation | |
Short circuit protection delay time | 200µS | |
Short circuit protection recovery | Disconnect load | |
Balanced turn-on voltage | 4.190V | 3.450V |
Balanced current | 60mA | |
Temperature protection value | 75 ͦ c | |
Temperature protection release value | 53 ͦ c | |
Discharge loop internal resistance | 20mΩ | |
Self-consuming in operating mode | 20µA | |
Working humidity in normal operating range | -20 – 70 ℃ | |
Storage temperature when Humidity<90%, No condensation | -40 – 85 ℃ | |
SIZE | 5.2*2.5*0.8 In | |
WEIGHT | 7 Ounce | |
JBD Wiring Diagram | JBD Wiring Diagram | |